Products: Test
Equipment
PathTrax 838
(310-010072-001)


-
Measures Path Loss, Signal Strength & Shielding Effectiveness
-
806-870MHz
-
Path Loss Accuracy: +/- 1 db Typ.
-
Receiver Range: 0 To -120 dBm
-
Transmitter Power: -30 To +30 dBm
-
Synthesized: 1 MHz, 100 KHz and 10 KHz
Step Size
-
Microprocessor Controlled
-
AC or Battery Operation
-
USB Controllable

The PathTrax model 838, is a user-friendly,
microprocessor-based transmitter and
receiver system that measures signal strength, path
loss, and shielding effectiveness in the GSM800 band. Lightweight and compact, each
PathTrax unit measures approximately 12" x 5" x 5"
and weighs 5.5 lbs., making PathTrax ideally suited
to field measurement tasks. Rugged construction
insures instrument survivability in a field test
environment.
PathTrax incorporates a self-calibrating
microprocessor-based architecture that provides for
ease of use. It requires only minimal operator
instruction for error-free operation. Its backlit LCD
output displays path loss measurements, battery
status, and other operating parameters.
PathTrax provides an optimum solution for
site surveys. Once the receiver is
calibrated with the transmitter, the receiver
measures pathloss directly. With a push of a
button, the receiver displays signal strength.
|
 |

|